The ETCR6300 high precision clamp licker is specially designed for AC leakage current measurement. It gets the latest digital integration and digital tomography technology, with small volume characteristics, high precision and perfect operation. It is widely used in the fields of electric power, telecommunications, meteorology, railway, oil construction, measurement, scientific research and teaching, industrial and mining enterprises, etc. almost free interference of external magnetic field.
RS232 interface is available on the meter. The meter can carry out real-time monitoring and historical queries; in dynamic display, with indication of maximum, minimum and average values; also setting alarm value and alarm indication function, reading historical data, saving and printing, etc.
The meter can be used for online measurement of alternating current below 600V, with peak hold, waiting read and data memory functions. All in all, it is accurate, easy and safe to use.
Technical specifications:
Function AC leakage measurement, AC current measurement, online AC current measurement
Power supply 6F22.9V
Process Type CT clamp, integral approach
4-Digit LCD Display Type
Clamp size 25 mm × 30 mm
LWH meter dimensions: 175 mm × 70 mm × 38 mm.
LCD screen size 35mm×21.5mm; Display dimension: 32mm×15mm
Sampling rate 2 times/second
Frequency 50Hz, 60Hz Automatic Identification
Automatic shifting
Range 0.000mA ~ 60.00A
Resolution 1uA
Accuracy ± 1.5% ± 5dgt (23℃±3, below 70%RH)
Mains voltage less than 600V AC
RS232 interface With RS232 interface, data stored in memory can be downloaded